CHAPTER 12 USER JUMPERS
Page 31
Figure 12-1 W8 user jumpers
DESCRIPTION
Eight jumpers are available at W8. These jumpers may
be read as part of a program to determine a boards
function or configuration. It is up to you to determine
what the jumpers mean. A common use is to set the
boards address in a RS-485 network.
Jumpers are at bank 6, address 1, bits 0-7.
Jumper W 8 is mapped to the following bit num bers.
Jumper Bit No.
[1-2] 0
[3-4] 1
[5-6] 2
[7-8] 3
[9-10] 4
[11-12] 5
[13-14] 6
[15-16] 7
Jumper status is read using the LINEB function. A ' 0'
indicates a jumper is installed.
100 A = LINEB(6,1)
Jumpers m ay be read to deter mine a car d address. Use
the following map to assign a value to a jumper. When
a jumper is installed, its value is 0. When r emoved, its
value is shown to the right. The pr ogram example
shows how a jumper configuration can be converted into
a number and a string. The values below are returned
for a position if other jumpers are installed.
Jumper Value
[1-2] 1
[3-4] 2
[5-6] 4
[7-8] 8
[9-10] 16
[11-12] 32
[13-14] 64
[15-16] 128
Assume W8[7-8] and [1-2] are not jum pered a nd all
others are. The program would return the following
value.
10 A = LINEB(6,1)
20 PRINT "Jumper value is:",A
RUN
Jumper value is: 9
Even if all jumpers are not installed, you can .A ND. out
jumper s not of intere st.