COUNTER/TIMERS BASIC SECTION 8
Page 8-1
Figure 8-1
INTRODUCTION
COUNTER/TIMERS SECTION 8
There is one counter input and two pulse ouputs
available on the RPC-210. C ounter input consists of
U21 is a counter/quadrature encoder IC. Its accumulator
is 24 bits wide (about 16 million counts). Maxim um
input frequency is 20 MHZ. The counter is software
program med for all of its modes.
If COM1 is not used, a pulse output from the UART
may be used for pulse generation.
The RTC can generate square waves from 2 to 32768
Hz.
These pulses may be used in conjunction with the
counter to measur e a pulse width or provide an alter nate
means of measuring time intervals between two events.
COUNTER/ENCODER
U21 may be programmed as an up/down or quadrature
encoder counter. A preset count may be loaded to
generate an interrupt (INT 0) when the count goes
through 0 or some other number. Counts may be read
“on the fly”.
J11 CONNECTOR PIN OUT
Pin # Description
1 Counter ‘B’ input
2 Counter ‘A’ input
3 Load counter (LCTR)
4 High frequency clock source (CO M1)
5 A-B Gate
6 Ground
7 Carry output
8 INT 0 (to CPU)
9 Borrow output
10 Latched carry or borrow output
PULSE OUTPUTS
A pulse output is available to perform timing functions.
This pulse is generated from the COM 1 UART (U13).
Since the UART is put into test mode, COM1 may not
be used for serial communication when it is generating
pulses.
Available clock outputs are 16X the baud rate. T hus,
pulses from 3.6864 MHZ to 9600 are available.