ANALOG I/O BASIC SECTION 10
Page 10-6
Gener ally, y ou have a fe w milli-am ps for your circ uit.
You may be able to get more than this in your
circumstance.
Unfortunately, the only way to tell is to try it. The best
way to tell is to connect the devices to the board and load
the ± supplies. M easure the voltages. J10-18 should be
at least 7.5V, if you will use the 0-5V A/D and D/A
range. J10-20 should be about -5V.
An alternative is to put analog I/O in the 2.5V max.
range. Then use the + 5V supply for amplifier supply.
APPLICATION PROGRAMS
Program s are in the BASIC52 directory.
Program Name Description
AIN-1.BAS All channels printed out,
including temperatur e. P rints
out actual voltage at pin.
AIN-2.BAS Performs timed A/D
conversions using ON TICK.
AIN-3.BAS Figures offset and gain error s.
Stores and retrieves calibration
constants.
210CAL.BAS Prompts you to adjust R16 and
calibrate each channel.
Requires an external reference
of 4.900 volts.
J10 ANALOG I/O CONNECTOR PIN OUT
The table below is a pin out for analog connector J10.
J1 Pin Name
1 Analog input 0
2 Ground
3 Analog input 1
4 Ground
5 Analog input 2
6 Ground
7 Analog input 3
8 Ground
9 Analog input 4
10 Ground
11 Analog input 5
12 Ground
13 Analog input 6
14 Ground
15 Analog input 7
16 Ground
17 Analog output 0
18 About + 8V
19 Analog output 1
20 About -8V